• MEDIUM
  • Research
  • Tier 1
  • Peer-Reviewed Research

Scan body optimisation for enhancing full-arch implant scanning accuracy using smartphone

Source
Clinical Oral Implants Research
Author
Yuqing Lu, Jiayi Yu, Fei Liu, Tim Joda, Junying Li

Summary and scoring by The Bell Brief (Dr. Jennifer Bell) using the Drill-Down Protocol. Not the original publisher.

Why it matters for dental

Specialists and DSOs evaluating full-arch implant workflows should note that a custom 3D-printed scan body improved the accuracy of a deep-learning smartphone video reconstruction method compared with stock PEEK scan bodies.

Key points

  1. 01

    DLC protocol using custom 3D-printed scan bodies achieved RMS trueness of 51.1 ± 7.6 μm versus 80.6 ± 27.8 μm for the DLS protocol using stock PEEK scan bodies.

  2. 02

    PG (photogrammetry) recorded the best precision across RMS (7.9 ± 3.3 μm), linear (8.7 ± 4.2 μm), and angular (0.07° ± 0.05°) measurements.

  3. 03

    Conventional splinted open-tray impressions produced the lowest RMS trueness value (23.1 ± 5.4 μm) among the four tested protocols.

  4. 04

    Neuralangelo software converted smartphone videos of a maxillary edentulous model with six implant analogues into 3D reconstructions for the DL groups.

Who should care

  • Specialist
  • Academia / research

Read the original

Clinical Oral Implants Research

Full reporting and any paywalled content live on onlinelibrary.wiley.com. We summarize and score; we do not republish.

Open original
4 stories

By email

Get The Bell Brief

Sorted for your role. Daily or weekly. Confirm by email, unsubscribe anytime.

How often