Probe accuracy and agreement and patient preferences in peri-implant probing depth

Source
Clinical Oral Implants Research
Author
Magdalena Mayol, Kristina Bertl, Nikolaos Pandis, Andreas Stavropoulos

Summary and scoring by The Bell Brief (Dr. Jennifer Bell) using the Drill-Down Protocol. Not the original publisher.

Why it matters for dental

Peri-implant probing depth accuracy matters for implant-maintenance protocols and early detection of peri-implant disease; metal and plastic probes showed comparable performance while the electronic probe proved unreliable.

Key points

  1. 01

    The metal and plastic probes differed from the correct peri-implant probing depth by less than 1.5 mm in approximately 80% of measurements and underestimated depth by an average of 0.5 mm.

  2. 02

    Metal probe accuracy was negatively influenced by a thick peri-implant mucosal phenotype.

  3. 03

    Patients reported significantly less pain and discomfort with the plastic probe than with the metal probe.

  4. 04

    The electronic probe differed from the correct peri-implant probing depth by 1.5 mm or more in 65% of measurements.