- MEDIUM
- Research
- Tier 1
- Mainstream Media
Dental Cements Show Distinct Fluoride and Hardness Profiles Across Exposure Protocols
- Source
- Bioengineer.org
- Originally at
- news.google.com(opens in a new tab)
Summary and scoring by The Bell Brief (Dr. Jennifer Bell) using the Drill-Down Protocol. Not the original publisher.
Why it matters for dental
Dentists who restore teeth in patients with gastric-acid exposure may see different fluoride release and surface durability depending on whether they select a conventional or resin-modified glass ionomer cement.
Key points
- 01
In vitro testing of Ketac Molar Easymix conventional glass ionomer cement recorded 3.81 mg/L fluoride release under simulated gastric acid versus 3.38 mg/L in distilled water.
- 02
In vitro testing of Fuji II LC resin-modified glass ionomer cement recorded 2.96 mg/L fluoride release under simulated gastric acid versus 3.87 mg/L in distilled water.
- 03
Fuji II LC resin-modified glass ionomer cement showed a drop in Vickers microhardness from 24.3 VHN in distilled water to 10.2 VHN under simulated gastric acid.
- 04
Ketac Molar Easymix conventional glass ionomer cement retained microhardness of 68.6 VHN under simulated gastric acid and 70.3 VHN in distilled water with no statistically significant difference.
Who should care
- Specialist
- Academia / research
Read the original
Bioengineer.org
Full reporting and any paywalled content live on news.google.com. We summarize and score; we do not republish.